QMC CENTRIFUGAL COMPRESSOR PROGRAM for Windows

The QMC Kilgore Centrifugal Compressor Program provides calculation of centrifugal compressor performance over a wide range of operations, including, but not limited to, start-up, normal operation at steady and varying load conditions, normal shutdown, emergency shutdown, and safety valve relieving conditions. A single compressor train with one or two services with a maximum of six stages (compressor sections) total can be simulated.

Input from compressor manufacturer's performance curves and data provides the basis for the generation of a mathematical model of each compressor stage (section).    This model develops adiabatic head versus actual volumetric inlet flow which is the basis for calculating performance over a wide range of conditions.

In the graphic display of operating maps below, notice that the surge line, anti-surge control line, operating point (and trace), and choke line are shown as well as much pertinent data.

SYSTEM FEATURES (optional) that can be simulated:

    Inlet Header
            Operating flow range or pressure range
            Pressure controller with control valve
                to vent excess

     Outlet Header
            Operating flow range or pressure range
            Pressure controller with control valve
                to vent excess.

     Compressor Suction (each stage)
            Inlet pressure controller and valve
                (1st stage only)
            Inlet excess pressure regulator valve
            Cooler (air or water cooled)

     Compressor Discharge (each stage)
            Pressure Safety Valve/s (PSV)
            Silencer for Safety Valve/s
            Emergency Vent Valve (blowdown)
            Cooler (air or water cooled)
            Anti-Surge Valve (may connect to suction same
                 or any previous stage)
            Interstage Options
                    Check valve installed
                    Check valve installed with anti-surge overlap
                    Check valve not installed
                    Check valve installed with bypass flow element
                    External balance gas flow connections

SYSTEM CONTROLLERS

    Main Unit Controller
            Control mode
                    No control
                    Discharge Pressure control
                    Inlet Header Pressure control
                    Discharge + Inlet Header Pressure control
                    Output from any above configuration
                          to set point on Discharge Flow Controller
            Unit Controller to control
                    RPM
                    Anti-surge valve
                    1st Stage inlet valve
                    External discharge to suction by-pass valve

    Anti-Surge Controllers

    Auxiliary Controllers
             Inlet Header Pressure Controller
             Outlet Header Pressure Controller
             Final Discharge Temperature Controller

    Control Parameters (adjustable)
             Reset (Integral)
             Gain  (Proportional)
             Derivative

    Induction Motor Driver
            Use motor manufacturer torque/RPM curve or
              program default curve for acceleration during start.

System Requirements

Available for: Win95/98/NT 
Minimum CPU Requirements: 486 
Minimum Ram: 8 MB 
Version: 6 
Published: 2000 

Top of Page

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 
E-mail Quality Monitoring & Control at QMC@QMC.net

If this page is without a left explorer menu, view the QMC Suite of Programs
Copyright © VB Quality Monitoring & Control, Inc.
All rights reserved.
All specifications subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.